The release of hydration heat that accompanies the hardening of concrete can cause a significant increase of the temperature in the component, especially in the case of bulky components. This gives rise to pressure forces that can cause cracks, if they exceed the tensile strength of the concrete, affecting its durability. Web-based data loggers (remote retrieval) allow for simultaneous long-term measuring and monitoring of multiple measuring points in mains or battery-powered operation.

The temperature increase can, for example, be recorded via an on-site test for concretes according to ZTV-W LB 215. The temperature is measured on large-format concrete blocks with an edge length of 2 m that are equipped with heat insulation. The applicable testing conditions are outlined in ZTV-W LB 215. Quasi-adiabatic conditions can therefore be assumed for these measurements. At the same time, manufacture-related effects from concrete production, transport and installation are simulated.

While the test is carried out on the concrete block, the concrete temperature is recorded for a period of at least seven days and analysed.

More projects

Lärmschutzwandanlagen reduzieren die Lärmbelastung an Bahnstrecken

Laminated safety glass noise protection wall elements along railway tracks

The aim is to develop concrete proposals for providing proof of usability for the transparent…

Read More

Fire resistance test for preserving the functionality of electric cable systems

MFPA Leipzig GmbH carried out a test on the functional integrity of electrical cable systems in…

Read More

Zum Nachweis der Stoßsicherheit der neuen Glasfassade des Leipziger Gewandhauses

Pendulum impact test to verify impact resistance

To verify the impact resistance of the new glass facade of the Leipzig Gewandhaus, MFPA Leipzig…

Read More